- On sale!
- Out-of-Stock
Menu
Menu
-
Video Surveillance
- Cables
- Power
- Tools
- IP Cameras
-
Accessories
- UTP Video Transceivers
- Dummy Cameras
- Video distributors
- Ground isolators
- Camera Housings
- IR and White Light Illuminators
- Camera Mounts
- DVR/NVR Steel Enclosures
- Junction Boxes
- PTZ Controllers
- CCTV Testers
- Lens
- Microphones
- Extender Kits, Converters, Splitters, HDMI, VGA, DVI
- Video Wireless Transmitter
- Complete Systems (Kits)
- Door Phones and Door Video Phones
- TurboHD Cameras (TVI) / AHD
- Surge Protection
- Mobile Video Recorders
- Servers / Storage / PC
- Monitors, Displays, Ergonomic Desks and Mounts
- Software VMS and Analytics
- Video Analytics
- Robots
- NDAA
-
Access Control
- Accessories
- Locks
- Hotel Management
- Guard Patrol Systems
- Standalone Keypads
- Access Control System
- Metal Detectors
- Bullet Proof Products
- Power Supplies
- Biometrics
- Identification and Credentialing
- Asset Protection(EAS)
- X-Ray and Explosives
- TV Door Phone and Interphones
- Tools
- Vehicular Access
- Surge Protection
- Emergency Systems
- Attendance Software
- Replacement Parts
- Readers
- Turnstiles and Flap Barriers
- tsesta
-
IntrusionSystems
- Honeywell Total Connect
- Alarm Panels
- Keypads
- Expansion Modules
- Cabinets and Enclosures
- Wires
- Power
- Access Control
- Magnetic Contacts
- Detectors/sensors
- Central Monitoring Stations
- Electric Fences
- Accessories
- Perimeter Protection
- Fogging Security Systems
- Over Loading Protection
- Tools
- Smart House - Automation
- Signaling
- Emergency Systems
- Public Address and Voice Alarm Systems
- Video verification
- Hikvision Alarm Panel & Accessories
-
FireDetection
-
Networking
- Tools
- Networking
- Voice Over IP - VoIP
- Antennas
- Towers and Masts
- Racks and Enclosures
- Surge Protection
- UPS/No-Breaks
- Servers and Storage NAS / SAN
- PtP and PtMP Links
- Backhaul Links
- Wi-Fi Networks
- Cellular Coverage for LTE 4G, 3G and Voice
- FTTH/PON Networks
- Audio, Video and Loudmouth Stand-Alone PA Systems
-
Structured Cabling
-
IoT / GPS / Telematics and Emergency Lights
-
Radio Communication
- Accessories for ICOM
- RF Filters and Systems
- Racks and Cabinets
- Accessories for KENWOOD
- Tools
- Accessories for Motorola, Hytera and others
- Outdoor/Indoor Enclousures
- Amateur ICOM Radios
- Amateur KENWOOD Radios
- Commercial KENWOOD Radios
- Digital NEXEDGE KENWOOD Radios
- Radio Dispatch Consoles
- IP Links(RoIP)
- Audio Recorders
- Applications and Solutions
- Antennas
- Surge Protection
- Laboratory equipment
- Duplexers, Pre-selectors and Combiners
- Power
- Racks and Accessories
- Cables
- Connectors, Jumpers and Adapters
- Towers and Masts
- Rack Organizer
- Enclosures and Accessories
- Amateur Radios
- Airband and Marine Radios
- Commercial Radios ICOM / KENWOOD
- Trunking Systems
- Adapters
- Connectors
- Spare parts
- Cellular Coverage 5G, 4G, 3G and Voice
- LTE Radios
- Marine Solution
- NXRADIO Accessories
- Repeaters
- RITRON Wireless Solutions
To request a quote send email to [email protected]
ALTRONIX AL400ULACM Access Power Controller w/ Power Supply/
AL400ULACM ALTRONIX Access Power Controller w/ Power Supply/Charger 8 Fused Relay Outputs 12/24VDC 4A FAI 115VAC BC400 Enclosure With backup battery capacity Requires battery AL400ULACM
Security policy
(edit with the Customer Reassurance module)
Delivery policy
(edit with the Customer Reassurance module)
Return policy
(edit with the Customer Reassurance module)
ALTRONIX AL400ULACM Access Power Controller w/ Power Supply/Charger 8 Fused Relay Outputs 12/24VDC 4A FAI 115VAC BC400 Enclosure With backup battery capacity Requires battery
Power supply for access control backup capacity for 12 and 24 Vdc 4 A 8 control circuits (NO) and 8 trigger circuits 8 Fail-Safe outputs and / or Fail Secure 8 relay outputs C voltage entry of: 115 Vca
Input
- Input 115VAC 60Hz rated 3.5A.
- Power supply input options:
a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power (external power supply is required). (Current is determined by the power supply connected not to exceed a maximum of 10A total).
- Eight (8) Access Control System trigger inputs.
-
Input options:
a) Eight (8) normally open (NO) inputs. - b) Eight (8) open collector inputs.
- c) Any combination of the above.
Output
- 12 VDC or 24VDC outputs.
- 12VDC 4A supply current or 24VDC 3A supply current.
- Class 2 Rated power limited outputs.
- Eight (8) independently controlled outputs.
-
Output options:
-
a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
b) Eight (8) form "C" 5A rated relay outputs.
b) Eight (8) form "C" 5A rated relay outputs.
c) Any combination of the above.
Eight (8) auxiliary power outputs (unswitched)
Output ratings:
- Eight (8) independently controlled outputs.
- Fuses are rated 3.5A.
- Filtered and electronically regulated outputs (built-in power supply).
- ACM8 board main fuse is rated at 10A.
Supervision
- AC fail supervision (form "C" contacts). Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
- Low battery and battery presence supervision (form "C" contact).
Features
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Fire Alarm disconnect input options:
- a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit.
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated 1A 28VDC not evaluated by UL).
- Short circuit and thermal overload protection.
-
Visual Indicators
- Short circuit and thermal overload protection.
- Red LEDs indicate outputs are triggered (relays energized).
- Green LED indicates FACP disconnect is triggered.
- AC input and DC output LED indicators.
-
Battery Backup
- AC input and DC output LED indicators.
- With backup battery capacity.
- Battery is not included.
- The battery can be: PL4.512 / PL712 / PL912.
- Built-in charger for sealed lead acid or gel type batteries.
- Automatic switch over to stand-by battery when AC fails.
- Zero voltage drop when unit switches over to battery backup (AC failure condition).
- Battery fail and battery presence supervision (form "C" contact).
-
Temperature - Battery fail and battery presence supervision (form "C" contact).
- Operating: 0ºC to 49ºC (32ºF to 120ºF).
- Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).
- Relative Humidity 85% /- 5%.
BTU/Hr. (approx.):
- Relative Humidity 85% /- 5%.
- 12VDC: 25 BTU/Hr.
- 24VDC: 37 BTU/Hr.
Enclosure
- Wall mount enclosure for indoor use.
- Accommodates up to two (2) 12VDC/12AH Batteries.
- Dimensions 12.25"W x 15.5"H x 4.5"D (311 mm W x 394 mm H x 114 mm D).
- 1.125" and 1.375" combination knockouts.
Weights (approximate)
- Product Weight: 10.7 Lbs. (4.85 kg).
- Shipping Weight: 12 Lbs. (5.44 kg).
2024-12-26 07:35:52