MACURCO - AERIONICS TX-6-AM Ammonia (NH3) Detector Controller and Transducer

 

• Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC

• Current 24 VDC: 75 mA in alarm 50 mA fan relay on and 23 mA stand by

• Shipping Weight: 1 pound (0.45 kg)

• Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)

• Color: Dark gray

• Connections: plugs/terminals

• Mounting box: (not included) 4x4 electric

• Fan relay: 5 A 240 VAC pilot duty SPDT latching or non-latching

• Fan relay actuation: selectable at OFF 15 20 25 (default) 30 35 40 45 50 55 60 65 70 or 75 ppm NH3

• Fan Delay Settings of 0 1 3 (default) 5 and 10 minutes

• Fan Minimum Runtime settings are OFF (default) 3 5 10 or 15 minutes

• Alarm relay: 0.5A 120 V 60 VA

• Alarm relay actuation: selectable N.O. default or N.C. TX-6-AM Rear View

• Alarm relay settings: OFF 25 30 35 40 45 50 55 60 65 70 75 (default) 80 85 90 95 or 100ppm NH3

• Current Loop 4-20 mA for 0-100 ppm NH3

• Operating Environment: 0°F to 125° F (-18°C to 52°C) 10 to 90% RH

 

Detection and Controller of Ammonia

The MACURCO TX6AM is a low voltage detector controller and transducer with a built-in double relay selectable output selectable output from 4-20 mA buzzer and digital screen is a electronic detection system used to measure the concentration of Ammonia (NH3) and provide feedback and control the automatic fan/extractor to reduce the concentration of NH3 in parking lots maintenance areas and other commercial applications.

 

Features:

UL list

- Mounting standard electrical box 4 "x 4"

- Capable of revealing concentrations of ammonia in the range of 1 to 75 ppm NH3

- Factory calibrated

- Activation of the selectable fan relay in: 15 20 25 (by default)  30 35 40 45 50 55 60 65 70 or 75 ppm NH3

- Capable of showing concentrations of CO in the range of 0 to 200 ppm

- Alarm relay of: NA or NC 0.5 A

 -Fan relay: SPDT 5 A

Design of supervised system: a problem in the detector will activate the fan and alarm

- Dimensions: 114 X 102 X 54 mm

2024-12-26 16:25:57

Page: 5

TX6AM MACURCO - AERIONICS Ammonia (NH3) Detector Controller and Transducer TX-6-AM

TX6AM

Reviews

Write your review

MACURCO - AERIONICS TX6AM Ammonia (NH3) Detector Controller

TX6AM MACURCO - AERIONICS Ammonia (NH3) Detector Controller and Transducer TX-6-AM

Write your review