- On sale!
- Out-of-Stock
-
Video Surveillance
- Cables
- Power
- Tools
- IP Cameras
-
Accessories
- UTP Video Transceivers
- Dummy Cameras
- Video distributors
- Ground isolators
- Camera Housings
- IR and White Light Illuminators
- Camera Mounts
- DVR/NVR Steel Enclosures
- Junction Boxes
- PTZ Controllers
- CCTV Testers
- Lens
- Microphones
- Extender Kits, Converters, Splitters, HDMI, VGA, DVI
- Video Wireless Transmitter
- Complete Systems (Kits)
- Door Phones and Door Video Phones
- TurboHD Cameras (TVI) / AHD
- Surge Protection
- Mobile Video Recorders
- Servers / Storage / PC
- Monitors, Displays, Ergonomic Desks and Mounts
- Software VMS and Analytics
- Video Analytics
- Robots
- NDAA
-
Access Control
- Accessories
- Locks
- Hotel Management
- Guard Patrol Systems
- Standalone Keypads
- Access Control System
- Metal Detectors
- Bullet Proof Products
- Power Supplies
- Biometrics
- Identification and Credentialing
- Asset Protection(EAS)
- X-Ray and Explosives
- TV Door Phone and Interphones
- Tools
- Vehicular Access
- Surge Protection
- Emergency Systems
- Attendance Software
- Replacement Parts
- Readers
- Turnstiles and Flap Barriers
- tsesta
-
IntrusionSystems
- Honeywell Total Connect
- Alarm Panels
- Keypads
- Expansion Modules
- Cabinets and Enclosures
- Wires
- Power
- Access Control
- Magnetic Contacts
- Detectors/sensors
- Central Monitoring Stations
- Electric Fences
- Accessories
- Perimeter Protection
- Fogging Security Systems
- Over Loading Protection
- Tools
- Smart House - Automation
- Signaling
- Emergency Systems
- Public Address and Voice Alarm Systems
- Video verification
- Hikvision Alarm Panel & Accessories
-
FireDetection
-
Networking
- Tools
- Networking
- Voice Over IP - VoIP
- Antennas
- Towers and Masts
- Racks and Enclosures
- Surge Protection
- UPS/No-Breaks
- Servers and Storage NAS / SAN
- PtP and PtMP Links
- Backhaul Links
- Wi-Fi Networks
- Cellular Coverage for LTE 4G, 3G and Voice
- FTTH/PON Networks
- Audio, Video and Loudmouth Stand-Alone PA Systems
-
Structured Cabling
-
IoT / GPS / Telematics and Emergency Lights
-
Radio Communication
- Accessories for ICOM
- RF Filters and Systems
- Racks and Cabinets
- Accessories for KENWOOD
- Tools
- Accessories for Motorola, Hytera and others
- Outdoor/Indoor Enclousures
- Amateur ICOM Radios
- Amateur KENWOOD Radios
- Commercial KENWOOD Radios
- Digital NEXEDGE KENWOOD Radios
- Radio Dispatch Consoles
- IP Links(RoIP)
- Audio Recorders
- Applications and Solutions
- Antennas
- Surge Protection
- Laboratory equipment
- Duplexers, Pre-selectors and Combiners
- Power
- Racks and Accessories
- Cables
- Connectors, Jumpers and Adapters
- Towers and Masts
- Rack Organizer
- Enclosures and Accessories
- Amateur Radios
- Airband and Marine Radios
- Commercial Radios ICOM / KENWOOD
- Trunking Systems
- Adapters
- Connectors
- Spare parts
- Cellular Coverage 5G, 4G, 3G and Voice
- LTE Radios
- Marine Solution
- NXRADIO Accessories
- Repeaters
- RITRON Wireless Solutions
ICOM OPC474 Radio Cloning Data Cable Replacement and Compati
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
ICOM OPC-474 Radio Cloning Data Cable Replacement and Compatible with ICOM IC-R2/R3 / A3/A4/A5/A6 / H2
The instructions for cloning certain Icom radios using the OPC474 Cloning Cable the information has been gleaned from the Icom documentation.
Where used below MASTER is the radio that has the programmed data SLAVE will be copied from the MASTER and any programming already stored on the SLAVE will be over-written.
To CLONE programmed data between radios the model and type must be the same
i.e. a 450 - 490 MHz 2 channel radio can program another 450 - 490 MHz 2 channel radio but cannot program a 400 - 430 MHz radio or a radio with more/fewer channels etc.
IMPORTANT NOTES:
Cloning between CPU revision 1. and CPU revision 2 is not possible. To check CPU revision;
While pushing P3 and ↑ turn the transceiver power on. CPU revision is displayed ("t" is displayed at the end of the revision number for Thailand versions).
The "Transceiver Data Out" must be checked for the MASTER transceiver (within CS-F3G). Otherwise the cloning between transceivers cannot be operated.
Cloning
- Remove the antenna from both radios (received signals may cause cloning errors).
- Connect the OPC-474 CLONING CABLE to the speaker jack of the master and slave transceivers.
- While pushing P0 and ↑ turn the MASTER transceiver power on to enter cloning mode.
- Repeat step (1) for the SLAVE transceiver.
"CLONE" appears and the transceivers enter the clone standby condition. - Push PTT on the MASTER transceiver to send data to the SLAVE.
"CLOUT" appears in the MASTER transceiver display.
"CL IN" appears automatically in the SLAVE transceiver display.
When cloning is finished "CLONE" appears in the MASTER transceiver display.
NOTE:
DO NOT push the PTT on either transceiver during cloning. This will cause a cloning error. - When cloning is finished turn the power for both radios off and remove the connecting cables. When powered on again the radios will return to normal operation.