• Out-of-Stock

FREEDOM COMMUNICATION TECHNOLOGIES R8000C Portable Communica

0 Review(s) 
R8000C FREEDOM COMMUNICATION TECHNOLOGIES Portable Communications System Analyzer 250 kHz - 1 GHz. R8000-C
R8000C
Sorry, This item is out of stock.

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

FREEDOM COMMUNICATION TECHNOLOGIES R8000-C Portable Communications System Analyzer 250 kHz - 1 GHz.


Communications System Analyzer 250 kHz - 1 GHz.

The R8000C is a unique device on the market since it has all the characteristics of a communications analyzer in a truly portable package. Easy to handle
combines the navigation keys and the segmentation of the screen in “zones” which is common in the FREEDOM Communication Technologies brand.

General Features:

  • Spectrum Analyzer
  • Signal Generator
  • Sensitive Measurement Receiver
  • Tracking Generator (optional)
  • SINAD Meter
  • Distortion Meter
  • Modulation Scope
  • Oscilloscope
  • Frequency Error Meter
  • Cable Fault Locator (optional)
  • FM Deviation Meter
  • AM Modulation Meter
  • Receive Signal Strength Meter
  • Broadband and Narrowband Power Meters
  • Audio Counter
  • Audio Generator
  • AC / DC Voltmeters
  • DMR (MOTOTRBO™) test mode (optional)
  • NXDN test mode (optional)
  • P25 test mode (optional)

Generator (Receiver test)

  • Port Protection Limit: 5W for 30 seconds
  • Frequency Range: 250 kHz to 1 GHz
  • Extended Frequency
  • Range (Optional): 250 kHz to 3 GHz
  • Frequency Resolution: 1 Hz

OUTPUT LEVEL GENERATE PORT

  • Range FM: 5 to -95 dBm below 2 GHz 5 to -95 dBm above 2 GHz
  • Range AM: -1 to -95 dBm below 2 GHz  -11 to -95 dBm above 2 GHz
  • Resolution: 0.1 dB
  • Accuracy: ±2 dB

OUTPUT LEVEL RF I/O PORT

  • Range FM: -30 to -130 dBm below 2 GHz  -40 to -130 dBm above 2 GHz
  • Range AM: -36 to -130 dBm below 2 GHz  -46 to -130 dBm above 2 GHz
  • Resolution: 0.1 dB
  • Accuracy: ±1 dB to 1GHz; ±2dB > 1 GHz

FM MODULATION

  • Deviation Accuracy: 5% of setting
  • Deviation Range: 0 to 75 kHz
  • Deviation Resolution: 10 Hz
  • Modulation Bandwidth: 5 Hz to 20 kHz

AM MODULATION

  • AM Depth Range: 0 to 90%
  • Resolution: 1% of setting
  • Modulation Bandwidth: 100 Hz to 10 kHz
  • Accuracy: 5% of setting

MODULATION TYPES

  • 1 kHz Tone Private Line Digital Private Line (w/ DPL (Invert) Single Tone DTMF Two-Tone Paging 5/6 Tone Paging POCSAG External Inputs from both a supplied microphone and BNC input.

Receiver (Transmitter test)

  • Frequency Range: 250 kHz – 1 GHz (3 GHz optional)

SENSITIVITY

  • Narrowband FM: 2.0 uV for 10 dB EIA SINAD
  • Wideband FM: 10 uV for 10 dB EIA SINAD
  • AM: 10 uV for 10 dB EIA SINAD

RF I/O PORT

  • VSWR: < 1.2 to 2 GHz ≤ 1.5 to 3 GHz
  • Max Power: 50 W for 5 minutes  150 W for 30 seconds (30 sec. on 5 min. off)
  • Absolute Max Power: 150 W
  • Alarm: Internal temperature alarm

ANTENNA PORT

  • Maximum Power: 0 dBm
  • Alarm: 10 dBm
  • IF FILTERS: 6.25 kHz 12.5 kHz 25 kHz  50 kHz 100 kHz 200 kHz

FREQUENCY ERROR MEASUREMENT

  • Type of Display: Autoranging
  • Resolution: 1 Hz

FM DEVIATION MEASUREMENT

  • Demodulation Range: Up to ±75 kHz
  • Accuracy: ±5% plus peak residual FM
  • Frequency Response: Selectable per the following:
  • Low Pass Filters: 300 Hz 3 kHz 20 kHz
  • High Pass Filters: 1 Hz 300 Hz 3 kHz

Demodulation

  • Output Level: 6.25 kHz B/W: 2.56V / 1 kHz
  • 12.5 kHz B/W: 1.28V / 1 kHz
  • 25 kHz B/W: 0.64V / 1 kHz
  • 50 kHz B/W: 0.32V / 1 kHz
  • 100 kHz B/W: 1.6V / 10 kHz
  • 200 kHz B/W: 0.8V / 10 kHz

Demodulation Output

  • Amplitude Flatness: 11 Hz to 7.92 kHz ±1.25 dB 5 Hz to 20 kHz ±2 dB

Demodulation

  • Output Impedance: 100 ohms nominal

AM MODULATION MEASUREMENTS

  • Demodulation Range: 0 to 100%
  • Accuracy: ±5% for levels below 80%
  • Frequency Response: Selectable per the following:
  • Low Pass Filters: 300 Hz 3kHz 20kHz
  • High Pass Filters: 1 Hz 300 Hz 3 kHz

Demodulation

  • Output Level: 0.8 V peak per 10% AM Modulation

Demodulation Ouput

  • Amplitude Flatness: 11 Hz to 7.92 kHz ±1.25 dB 5 Hz to 20 kHz ±2 dB
  • Output Impedance: 100 ohms nominal

DISTORTION METER

  • Range: 1% to 20%
  • Distortion Accuracy: The greater of: ±0.5% of distortion or ±10% of reading
  • Input Level: 0.1 V rms min

2024-12-25 16:25:18

Page: 2

R8000C FREEDOM COMMUNICATION TECHNOLOGIES Portable Communications System Analyzer 250 kHz - 1 GHz. R8000-C

R8000C

Reviews

Write your review

FREEDOM COMMUNICATION TECHNOLOGIES R8000C Portable Communica

R8000C FREEDOM COMMUNICATION TECHNOLOGIES Portable Communications System Analyzer 250 kHz - 1 GHz. R8000-C

Write your review